Evacuating And Charging Valve, Removing And Installing, Low And High Pressure Side: Removing
-- For all the following work, close the open lines and connections with clean plugs from the Engine Bung Set :VAS6122 .
-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
Danger of frostbite due to refrigerant coming out under pressure.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- Evacuate or drain refrigerant and open the refrigerant circuit immediately.
- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit has not been opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.
-- Remove the valve -2- together with the Socket :T10364/4A