Dryer Cartridge, Removing And Installing, SHOWA/KEIHIN Condenser: Installing
Install in the reverse order of removal while noting the following:
- Replace the plug, O-ring and dryer cartridge after every opening of the receiver/dryer. Refer to Parts Information.
- Keep the dryer cartridge sealed in its air-tight packaging as long as possible. Open the package just before inserting the dryer cartridge in the condenser. The dryer cartridge absorbs moisture from the surrounding air in a very short time and becomes unusable.
-- Using the opening, inspect the receiver/dryer on the condenser for dirt and damage on the threaded- and sealing surfaces.
-- Coat the O-ring with refrigerant oil before installing. Refer to SEALS AND GASKETS .
-- Lightly coat the filter element -F- in the sealing surface area -J- with refrigerant oil before installing. Refer to SEALS AND GASKETS .
-- Using a suitable tool -K-, insert the filter element -F- on the correct side all the way into the mount in the receiver/dryer. While doing so, do not damage the braces -H-.
-- Assemble the plug -A- with the O-ring seals -B and C- and the support ring -D-.
-- Remove the dryer cartridge -E- from the package and insert it into the receiver/dryer.
-- Position and install the plug -A-.
-- Evacuate and charge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
-- Operate the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .