Thermal Management Coolant Temperature Sensor 4 -G905-, REMOVING AND INSTALLING, AUDI A6/A7
WARNING: This page is about a different car, the 2024 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
Procedure
CAUTION:
A partial coolant replacement in the engine coolant circuit is not possible on vehicles with a high-voltage system.
For repairs and partial replacement on the engine coolant circuit the entire coolant must be drained and refilled.
-- Drain the coolant. Refer to DRAIN THE COOLANT .
-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .
-- Disconnect the connector -3-.
-- Remove the bolt -2-, and remove the Thermal Management Coolant Temperature Sensor 4 -G905- -item 1-.
- Allocation of the O-ring/centering ring. Refer to Figure.
-- Fill the cooling system. Refer to COOLANT, FILLING USING Cooling System Charge Kit:VAS 6096 [DMTA, DPAA, DPUA, DPVA, DMTC, DRYA, DUVA] .
Tightening Specifications