Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4: Installing
Install in the reverse order of removal while noting the following:
-- It must be checked, if the foam ring -2- is placed over the grommet -1-.
-- Insert the battery -3-, at the same time insert the pressure equalization opening -arrow- into the grommet.
-- Check the pressure equalization opening -arrow- for correct seating in the grommet, for this, loosen the right underbody trim panel at the inside. Refer to OVERVIEW - UNDERBODY TRIM PANELS .
-- When the ignition and electrical equipment are switched off, connect the battery in the following sequence:
-- Connect the battery terminal connectors -1 and 3-.
-- Connect the connector -2-.
-- Check the battery for secure fit after installation.
-- Connect the Battery -A- and re-energize the 48V system. Refer to Battery -A-, DISCONNECT AND CONNECT, 0K4 .
-- If the Battery, 48 V -A6- was replaced, the new Battery, 48 V -A6- must be adapted.
Procedure
-- Connect the Vehicle Diagnostic Tester.
-- Select the Diagnostic mode and start the diagnosis.
-- Select the Test plan tab.
-- Select the Select individual test button and select the following tree structure consecutively:
- Diagnostic-capable systems
- 0021 - 48V Battery Management -A6-
- 0021 - 48V Battery Management, functions
- 0021 - Replacing Control Module (Battery, 48 V -A6-)
-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.