LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2024 >> S3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 203 (Air Conditioning (Heating, Ventilation And Air Conditioning - Component Location Overview)) >> 87 Air Conditioning >> Refrigerant Circuit >> High Pressure Sensor -G65-, REMOVING AND INSTALLING >> Removing

High Pressure Sensor -G65-, REMOVING AND INSTALLING: Removing

WARNING: This page is about a different car, the 2024 Audi A4 allroad. However, it is still accessible from the selected car via links, so may be relevant.

-- Switch off the ignition.

-- Remove the lock carrier cover. Refer to Front Bumper .

Q5

-- If installed, remove the upper radiator shutter. Refer to OVERVIEW - RADIATOR/RADIATOR FAN .

RS 5 from Product Improvement

GWWA87-12867Courtesy of AUDI OF AMERICA, LLC

-- Remove the bolt -2-.

-- Only slightly loosen the bolt -1-.

-- Pull forward the bumper cover bracket in direction of -arrow-.

GWWA87-12868Courtesy of AUDI OF AMERICA, LLC

Continuation for All Vehicles

-- Disconnect the connector -1-.

CAUTION:

Danger or frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- If refrigerant flows out of the refrigerant line longer than 1 second when loosening the pressure sensor, tighten the pressure sensor and replace the faulty check valve.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the High Pressure Sensor -G65- -2- with the Socket - 24mm :T40284  from the connection on the condenser.