Home >> Audi >> 2024 >> S3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 18 (Air Conditioning (Refrigerant R134A Servicing) (Pressures, Checking)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Leak Detection On Refrigerant Circuit Using Leak Detection Kit:Vas6201A >> Adding UV-Leak Detection Additive when the Refrigerant Circuit is Empty

Adding UV-Leak Detection Additive when the Refrigerant Circuit is Empty

WARNING: This page is about a different car, the 2022 Audi S3, 2022 Audi RS 3, 2022 Audi A3 Quattro, and 2022 Audi A3. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Cartridge & One Unit
GWWA87-0490Courtesy of AUDI OF AMERICA, LLC

The cartridge -A- contains 15.4 ml of UV-leak detection additive (one unit -B- corresponds to 2.5 ml).

-- Assemble the Leak Detection Kit :VAS6201A  -1- with the cartridge -2- Leak Detection Kit - Cartridge :VAS6201/2  .

Fig 2: Assembling Hand Pump VAS 6201 With Cartridge - VAS 6201/2
GWWA87-0496Courtesy of AUDI OF AMERICA, LLC

-- Insert the Leak Detection Kit - Filler Tube :VAS6201/8  . Refer to Add UV-Leak Detection Additive using the in the Refrigerant Circuit - Leak Detection Kit - Filler Tube:VAS6201/8  -item 7- into the hand pump.

-- Open the hand pump service valve.

NOTE:

UV-Leak detection additive is best added to the empty refrigerant circuit via a service connection or an opened connection.

If the refrigerant circuit is empty, then it is better to add the UV-leak detection additive via a connection point (for example, when the connection point is already open). This way no UV-leak detection additive remains in the service connection and the connection does not need to cleaned.