LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2024 >> S3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 18 (Air Conditioning (Refrigerant R134A Servicing) (Pressures, Checking)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> General Information

General Information

WARNING: This page is about a different car, the 2022 Audi S3, 2022 Audi RS 3, 2022 Audi A3 Quattro, and 2022 Audi A3. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:

There is a risk of freezing.

Refrigerant may leak out if refrigerant circuit is not discharged.

NOTE:

Minor leaks can be detected using an electronic leak detector or UV leak detector lamp.

This Service Information describes two different methods for detecting leaks in the refrigerant circuit. These methods have been tested and result in success when used correctly.

Many methods for detecting leaks in the refrigerant circuit are offered in the open market. These methods do not always have optimum results and if they are not performed exactly to the specification and may result that several components in the refrigerant circuit have leaks. Also, refrigerant circuit components can be damaged by some methods.

CAUTION:
  • Audi does not approve the use of chemicals to seal leaks in the refrigerant circuit (leak stop additives).
  • Chemicals that seal leaks in the coolant circuit form deposits that affect the function of the A/C system and lead to A/C system failure (and failure of the A/C service station).
NOTE:

Chemical materials (leak stop additives) to seal leaks in the refrigerant circuit react with air or the moisture in the air and form deposits in the refrigerant circuit (and in the A/C service station) that lead to malfunctions in the valves and other components that come into contact with such chemicals. These deposits cannot be removed completely from the components, even by flushing. It is only possible to service the refrigerant circuit by replacing all the components which come in contact with this material.