Requirements for Calibrating
- The camera lens must be clean.
- The vehicle must be standing on a firm and level surface.
- There must be sufficient open space around the vehicle.
- The parking brake must be set.
- The steering wheel must be in the 0 position and the wheels must be straight.
- All doors, the rear lid must be closed.
- There are no people in the vehicle.
- The vehicle is not loaded (curb weight).
- Before each calibration: turn on the ignition.
The Calibration Unit:VAS6350A consists of the following parts:
- Calibration Tool - Wheel Center Mountings:VAS6350/1
- Calibration Tool - Spacing Laser:VAS6350/2
- Calibration Tool - Linear Laser:VAS6350/3A
The vehicle in the illustration below is only a basic outline.
- Calibration Tool - Wheel Center Mountings:VAS6350/1
- With wheel bolt adapter and measuring paddle
- Right/Left Catch Bracket
- To mount the Spacing Laser:VAS6350/2A for the distance measurement
- Plastic Foot
- Quantity: 3
- Adjustable for adjusting the horizontal position of the Calibration Tool:VAS6350A
- Calibration Tool - Linear Laser:VAS6350/3A
- With "laser protective eyewear"
- On the Calibration Tool:VAS6350A
- Refer to Calibration Tool - Line Laser:VAS6350/3A Owner's Manual for handling.
- Calibration Tool - Spacing Laser:VAS6350/2A
- For distance measurement
- Refer to the Calibration Tool - Spacing Laser:VAS6350/2A Operating Instructions for handling.
- Calibration Tool:VAS6350A
- Between the catch bracket on the calibration board and the Calibration Tool - Wheel Center Mounting:VAS6350/1A - dimension -a- : 1.47 m to 1.90 m
- Level
- On the Calibration Tool:VAS6350A
- For checking the horizontal position
Calibration board orientation
-- Position the calibration platform behind the vehicle at a distance of 1.47 m to 1.90 m to the rear wheels, see -dimension A- in the overview illustration. Refer to Calibration Unit: VAS6350A, INSTALLING AND ALIGNING .
-- Bring the Calibration Tool:VAS6350A into a horizontal position.
-- Twist the plastic feet under the calibration board so that the air bubble in the level is located exactly in the center of the indicator -arrow-.
-- Wear "laser protective eyewear".
-- Turn on the Calibration Tool - Linear Laser:VAS6350/3A -1- on the Calibration Tool:VAS6350A .
-- Align the :VAS6350A so that the :VAS6350/3A -1- strikes the center of the emblem -2- on the rear lid.
-- Check that the Audi rings are centered on the rear. Correct the laser beam accordingly.
Continue calibrating the Rearview Camera -R189-.Refer to Rearview Camera -R189-, CALIBRATING .