Home >> Audi >> 2024 >> A7 Quattro Premium >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (Tools & Testing Equipment) >> 87 Air Conditioning >> Working With A/C Service Station >> Refrigerant, Filling In Reservoir

Refrigerant, Filling In Reservoir

-- Connect the cylinder with fresh refrigerant R1234yf to the service coupling on the low pressure side on the A/C Service Station. Refer to the A/C Service Station Owner's Manual.

-- Perform a gas analysis for the refrigerant to be filled (from the cylinder) using the A/C Service Station. Refer to REFRIGERANT GAS ANALYSIS, PERFORMING .

CAUTION:

There is a risk of explosion due to overfilling refrigerant cylinders.

Refrigerant can expand and the refrigerant cylinder can explode due to overfilling.

- Use a refrigerant cylinder with a safety valve.

- Never exceed the permitted capacity of the refrigerant cylinder.

NOTE:

Depending on the version of the A/C Service Station and the work procedures to be performed, there must be a certain minimum amount of refrigerant, refrigerant oil and UV-leak detection additive in the respective reservoirs on the A/C Service Station. Refer to the A/C Service Station Owner's Manual.