Home >> Audi >> 2024 >> A7 Quattro Premium >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Heating, Ventilation And Air Conditioning) (Component Location) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Shut-Off Valve -V424-, REMOVING AND INSTALLING >> Installing

Refrigerant Shut-Off Valve -V424-, REMOVING AND INSTALLING: Installing

Fig 1: Exploded View Of High-Voltage Battery Heater Core Refrigerant Shut-Off Valve -N542- With O-Ring
GWWA87-11597Courtesy of AUDI OF AMERICA, LLC

Install in the reverse order of removal while noting the following:

-- Replace the O-ring seals -B- and coat lightly with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT SEALS .

-- Tighten the union nuts -A and C- all the way by hand.

-- Check the location of the refrigerant lines using the label applied during removal for the Refrigerant Shut-Off Valve -V424- -D- and correct if necessary.

-- Tighten the union nuts -A and C- while counterholding the Refrigerant Shut-Off Valve -V424- -D- and make sure the refrigerant lines are routed without tension.

-- Check the routing after securing refrigerant lines. They must be inserted in their brackets and must not come into contact with other components.

-- Evacuate and fill the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

-- Switch the ignition on.

-- Initiate the basic setting of the A/C system using the Thermal Management Control Module -J1024- and activate the electric valves using the routine Stop routine refrigerant circuit filling/flushing  in the Vehicle Diagnostic Tester.

-- Operate the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT, VEHICLES WITH HIGH-VOLTAGE SYSTEM .