Home >> Audi >> 2024 >> A7 Quattro Premium >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Heating, Ventilation And Air Conditioning) (Component Location) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Lines, Disconnecting And Connecting From Condenser >> Refrigerant Lines, Disconnecting And Connecting At Condenser, 4-Cylinder S6/S7 TFSI >> Removing

Refrigerant Lines, Disconnecting And Connecting At Condenser, 4-Cylinder S6/S7 TFSI: Removing

-- Switch the ignition off.

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

4-Cylinder TDI

-- Remove the left air intake grille. Refer to OVERVIEW - BUMPER COVER .

S6/ S7 TFSI

-- Remove the bumper cover end plate. Refer to OVERVIEW - BUMPER COVER .

Continuation for All Vehicles

GWWA87-11919Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the bolt -C-.

-- Remove the refrigerant lines -B and D- from the condenser.

-- Seal the open lines and connections with clean plugs from the Engine Bung Set :VAS6122  .