LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2024 >> A7 Quattro Premium >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Heating, Ventilation And Air Conditioning) (Component Location) >> 87 Air Conditioning >> Refrigerant Circuit >> High Pressure Sensor -G65-, REMOVING AND INSTALLING >> Removing

High Pressure Sensor -G65-, REMOVING AND INSTALLING: Removing

-- Switch the ignition off.

-- Remove the lock carrier cover. Refer to Front Bumper .

Version 1

GWWA87-12095Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -D-.

CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- If refrigerant flows out of the refrigerant line longer than 1 second when loosening the pressure sensor, tighten the pressure sensor and replace the faulty check valve.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the High Pressure Sensor -G65- -A- from the connection on the condenser -C-.

Version 2

GWWA87-11736Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -D-.

CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- If refrigerant flows out of the refrigerant line longer than 1 second when loosening the pressure sensor, tighten the pressure sensor and replace the faulty check valve.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the High Pressure Sensor -G65- -A- with the Socket - 24mm :T40284  from the connection on the condenser -C-.