LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2024 >> A7 Quattro Premium >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Heating, Ventilation And Air Conditioning) (Component Location) >> 87 Air Conditioning >> Refrigerant Circuit >> Expansion Valve, Removing And Installing >> Removing

Expansion Valve, Removing And Installing: Removing

Vehicles with High-Voltage System

-- Switch off (deactivate) the "parking air conditioner". Refer to Owner's Manual.

-- Switch the ignition on.

-- Initiate the basic setting of the A/C system using the Thermal Management Control Module -J1024- and open the electric valves using the routine Refrigerant Circuit, Extract, Evacuate and Fill  in the Vehicle Diagnostic Tester.

-- Switch the ignition off.

Continuation for All Vehicles

-- Remove the plenum chamber bulkhead. Refer to PLENUM CHAMBER BULKHEAD, REMOVING AND INSTALLING .

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

GWWA87-12422Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the nut -A-.

-- Remove the refrigerant lines -B and C- from the front expansion valve -E-.

-- Remove the bolts -A-.

GWWA87-11745Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the expansion valve -B- from the refrigerant lines to the evaporator.