Home >> Audi >> 2024 >> A7 Quattro Premium >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Heating, Ventilation And Air Conditioning) (Component Location) >> 87 Air Conditioning >> Refrigerant Circuit >> A/C Pressure/Temperature Sensor -G395-, REMOVING AND INSTALLING >> Removing

A/C Pressure/Temperature Sensor -G395-, REMOVING AND INSTALLING: Removing

Working on a high-voltage system when activated or with the ignition turned on

-- Switch off (deactivate) the "parking air conditioner". Refer to Owner's Manual.

-- Switch the ignition on.

-- Initiate the basic setting of the A/C system using the Thermal Management Control Module -J1024- and open the electric valves using the routine Refrigerant Circuit, Extract, Evacuate and Fill  in the Vehicle Diagnostic Tester.

-- Switch the ignition off.

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

-- Since there is a risk of interchanging with other connectors or sensors, label the connector -A- and sensor -B-.

GWWA87-12825Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -A-.

-- Check the refrigerant line and connection -D- for contamination and clean if necessary.

CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Loosen and remove the sensor -B-.

-- Seal the open connection -D- with clean plugs from the Engine Bung Set :VAS6122  .