Heat Pump Valve Unit, Removing And Installing, 4-Valve Block Through 02/2021: Installing
-- Insert the heat pump valve unit -G- in the bracket and insert the bolts -A and E-.
-- Mount the refrigerant lines -B and F- on the valve unit for the heat pump operation and install the bolts -C and D-.
Install in the reverse order of removal while noting the following:
- Replace the O-rings. Refer to REFRIGERANT CIRCUIT SEALS .
- There can be refrigerant oil in the removed valve block that must be redelivered to the refrigerant circuit (with the new component). Refer to Refrigerant Circuit Components, Replacing or COMPONENTS, REPLACING .