Home >> Audi >> 2023 >> RS 5 >> Repair and Diagnosis >> External Pages >> Different car >> Section 315 (Controls, Housing (Servicing - 7-Speed Dual Clutch Transmission 0CJ, 0CL, 0CK, 0DK, 0DN, 0DP, 0HL) (Coupe)) >> 34 Controls, Housing >> MECHATRONIC >> Hydraulic Pressure Sensor 1 -G545- AND Hydraulic Pressure Sensor 2 -G546-, REMOVING AND INSTALLING >> Notes

Hydraulic Pressure Sensor 1 -G545- AND Hydraulic Pressure Sensor 2 -G546-, REMOVING AND INSTALLING: Notes

WARNING: This page is about a different car, the 2024 Audi A5 Quattro and 2023 Audi A5 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

CAUTION:

The system is under pressure.

  • Deactivate the ATF pump and drain the hydraulic pressure reservoir before removal.

-- Using the Vehicle Diagnostic Tester, empty the ATF pressure reservoir in the Transmission Control Module -J217- and disable the Transmission Fluid Auxiliary Hydraulic Pump -V552-. Refer to ATF PUMP, DEACTIVATING AND DRAINING THE HYDRAULIC PUMP RESERVOIR .

-- Remove the transmission fluid pan. Refer to TRANSMISSION FLUID PAN, REMOVING AND INSTALLING .

-- Release the catches -arrow A- of the connector for the Hydraulic Pressure Sensor 1 -G545- -1- and Hydraulic Pressure Sensor 2 -G546- -2- and disconnect from the Transmission Control Module -J217-.

GWWA34-11455Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector using the Assembly Tool:T40305  .

GWWA34-11746Courtesy of AUDI OF AMERICA, LLC

-- Loosen the bolts in the sequence -7 to 1-.

Fig 1: Hydraulic Pressure Sensor 1 And Hydraulic Pressure Sensor 2 - Tightening Sequence
GWWA34-11459Courtesy of AUDI OF AMERICA, LLC

-- Remove the Hydraulic Pressure Sensor 1 -G545- -1- and Hydraulic Pressure Sensor 2 -G546- with the retaining plate -arrow A- and wiring guide -arrow B-.

Installing

GWWA34-11463Courtesy of AUDI OF AMERICA, LLC

-- Coat the new seal -1- with ATF and install in the valve body as shown.

-- Install the wiring guide -2- with both bolts -arrows- hand-tight.

-- Install the Hydraulic Pressure Sensor 1 -G545- -1- and Hydraulic Pressure Sensor 2 -G546- with the retaining plate -arrow A- and bolts -1 to 5- hand-tight.

Fig 2: Hydraulic Pressure Sensor 1 And Hydraulic Pressure Sensor 2 - Tightening Sequence
GWWA34-11459Courtesy of AUDI OF AMERICA, LLC

-- Clip in the Hydraulic Pressure Sensor 1 -G545- -1- and the Hydraulic Pressure Sensor 2 -G546- into the wiring guide, then engage the Transmission Control Module -J217-.

GWWA34-11458Courtesy of AUDI OF AMERICA, LLC

-- Tightening specification and sequence. Refer to OVERVIEW - MECHATRONIC .

-- Install the connector with the Assembly Tool:T40305  .

GWWA35-10541Courtesy of AUDI OF AMERICA, LLC

-- Install the transmission fluid pan. Refer to TRANSMISSION FLUID PAN, REMOVING AND INSTALLING .

-- After replacing the Hydraulic Pressure Sensor 1 -G545- -1- and Hydraulic Pressure Sensor 2 -G546-, the clutch valves must be calibrated in the Transmission Control Module -J217-.