Home >> Audi >> 2023 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 349 (Cooling System (6-Cylinder Direct Fuel Injection 2.9L; 3.0L 4V TFSI Engine Ea 839) (Convertible)) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Electric Coolant Pump, Removing And Installing >> After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, 2.9L ENGINE >> Removing

After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, 2.9L ENGINE: Removing

WARNING: This page is about a different car, the 2024 Audi S5 and 2023 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the right catalytic converter (refer to CATALYTIC CONVERTER, REMOVING AND INSTALLING ) move with the heated oxygen sensor connected to the side and secure, to do so free up the wire.

-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING, 2.9L ENGINE .

-- Remove the double bolt -2- and bolts -1- and remove the bracket for the After-Run Coolant Pump -V51-.

GWWA19-12538Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -3-.

GWWA19-12541Courtesy of AUDI OF AMERICA, LLC

-- Tighten the bolt -arrow- using the :T10405  .

-- Loosen the hose clamp -1- and remove the After-Run Coolant Pump -V51- -2-.