Coolant Recirculation Pump -V50-, REMOVING AND INSTALLING, 2.9L ENGINE: Removing
WARNING: This page is about a different car, the 2024 Audi S5, 2024 Audi RS 5, 2023 Audi S5, and 2023 Audi RS 5. However, it is still accessible from the selected car via links, so may be relevant.
-- Remove the right front muffler. Refer to FRONT MUFFLER, REMOVING AND INSTALLING .
-- Disconnect the connector -3-.
-- Push the heat shield slightly upward.
-- Loosen the hose clamps -2- to clamp off the coolant hoses with the :3094 and remove them.
-- Remove the bolt -arrow- and remove the Coolant Recirculation Pump -V50- with bracket.
-- Remove the bolts -arrows- and remove the coolant pump -2- from the bracket -1-.