COOLANT, FILLING USING Cooling System Charge Kit:VAS 531 011 [DMTA, DPAA, DPUA, DPVA, DMTC, DRYA, DUVA]
Special tools and workshop equipment required
- Cooling System Charge Kit:VAS 531 011
Requirement
- Coolant drained. Refer to DRAIN THE COOLANT .
- Pay attention to the Owner's Manual for Cooling System Charge Kit:VAS 531 011
Procedure
-- Fill the "new" container from the Cooling System Charge Kit:VAS 531 011 with at least 10 liters of coolant in the correct mixture ratio.
-- Make sure that all coolant hoses are connected.
-- Connect the Cooling System Charge Kit:VAS 531 011 refer to the operating instructions.
-- Select "vehicle maintenance" in the main menu.
-- Select "pressure test" in the menu and perform the hydraulic pressure test.
- Test length => 10 s
- Maximum Delta P => 100 mbar (1.45 psi)
- Pressure test => 2700 mbar
- Pay attention to the notes on the display.
- After completing the test the result is displayed.
-- Select "vacuum test" in the menu and perform the hydraulic pressure test.
- Vacuum time => 240 s
- Specified pressure => 40 mbar (0.58 psi)
- Test length => 5 s
- Maximum Delta P => 10 mbar (0.15 psi)
- Pay attention to the notes on the display.
- After completing the test the result is displayed.
- If necessary repeat the procedure.
-- Select "system filling" in the menu and perform the filling.
- Capacity => enter 10000 g, corresponds to 10 liters.
- When the filling procedure is complete the display shows the coolant quantity filled.
- When the filling procedure is completed the service system automatically starts the cleaning of the hoses.
- Follow the instructions on the display and do not interrupt the procedure under any circumstances.
Continuation of the filling procedure:
-- Bleed the cooling system. Refer to BLEED COOLING SYSTEM. .