Home >> Audi >> 2022 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 201 (Cooling System (6-Cylinder Direct Injection 3.0L 4V TFSI Engine Ea839)) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Electric Coolant Pump, Removing And Installing >> After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, AUDI Q7 THROUGH PRODUCT IMPROVEMENT >> Removing

After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, AUDI Q7 THROUGH PRODUCT IMPROVEMENT: Removing

WARNING: This page is about a different car, the 2024 Audi Q7 and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .

-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING .

Vehicle without Parking Heater:

GWWA19-12534Courtesy of AUDI

-- Lift the clamp -1- and remove the coolant hose.

-- Open the retainer -arrow- and push the Coolant Recirculation Pump -V50- to the side.

-- Remove the nuts -arrows- and remove the bracket -1- for the Coolant Recirculation Pump -V50-.

GWWA15-12051Courtesy of AUDI
NOTE:

Ignore -item 2-.

Continuation for All Vehicles:

GWWA19-12538Courtesy of AUDI

-- Remove the double bolts -2- and bolts -1- and remove the bracket for the After-Run Coolant Pump -V51-.

-- Release and disconnect the connector -3-.

GWWA19-12541Courtesy of AUDI

-- Remove the bolt -arrow- using the Socket:T10405  .

-- Loosen the hose clamp -1- and remove the After-Run Coolant Pump -V51- -2-.