LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2022 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 121 (Cooling System (4-Cylinder Direct Injection 2.0L 4V TFSI Engine (Ea 888EVO4)) (DPVA)) >> 19 Cooling System >> Coolant Pipes >> Coolant Pipes, Removing And Installing >> COOLANT PIPE UNDER Hybrid Battery Unit -AX1-, REMOVING AND INSTALLING >> Removing

COOLANT PIPE UNDER Hybrid Battery Unit -AX1-, REMOVING AND INSTALLING: Removing

WARNING: This page is about a different car, the 2024 Audi Q5 and 2023 Audi Q5. However, it is still accessible from the selected car via links, so may be relevant.

-- Drain the coolant. Refer to COOLANT, DRAINING, HIGH-VOLTAGE COOLING CIRCUIT .

-- Remove the subframe. Refer to OVERVIEW - SUBFRAME .

-- Remove the nuts -3-.

GWWA19-13175Courtesy of AUDI OF AMERICA, LLC
CAUTION:

There is a risk of damaging the straps on the plastic coolant pipes if they are handled incorrectly.

- Counterhold at the coolant pipe when disconnecting and connecting the coolant hose.

-- Remove the coolant hoses -1 and 5- to do so loosen the hose clamps using Hose Clip Pliers:VAS 6362  .

-- Remove the coolant pipe -2-.