After-Run Coolant Pump -V51-, REMOVING AND INSTALLING: Removing
-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .
-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING .
Audi Q7 Until Product Improvement without Auxiliary Heating:
-- Lift the clamp -1- and remove the coolant hose.
-- Open the retainer in direction of -arrow- and push the Coolant Recirculation Pump -V50- to the side.
-- Remove the nuts -arrows- and remove the bracket -1- for the Coolant Recirculation Pump -V50-.
Ignore -2-.
Continuation for All Vehicles:
-- Remove the double bolts -2- and bolts -1- and remove the bracket for the After-Run Coolant Pump -V51-.
-- Release and disconnect the connector -3-.
-- Remove the bolt -arrow- using the Socket - T30: T10405 .
-- Loosen the hose clamp -1- and remove the After-Run Coolant Pump -V51- -2-.