Home >> Audi >> 2022 >> Q3 Premium Plus >> Repair and Diagnosis (Single Page) >> Electrical >> Charging System (Battery, Starter, Generator), Cruise Control >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Battery, Removing And Installing >> Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4 >> Installing

Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4: Installing

GWWA27-10955Courtesy of AUDI OF AMERICA, LLC

Install in reverse order of removal and note the following:

-- Slide the battery with protective housing all the way onto the retaining bracket -2- so that the clamping strip engages in the retaining bracket.

-- Check the protective housing for secure fit after installation.

-- Check the pressure equalization hose to make sure it is seated correctly in the grommet -1-.

-- When the ignition and electrical equipment are switched off, connect the battery in the following sequence:

-- First connect the battery positive cable terminal to the battery positive terminal "+" by hand and tighten the nut.

-- Connect the battery ground cable terminal clamp to the battery negative terminal "-" by hand and tighten the nut.

-- Attach the cap until it engages audibly.

-- Connect the connector.

-- Check the battery for secure fit after installation.

-- Connect the Battery -A- and re-energize the 48V system. Refer to Battery -A-, DISCONNECTING AND CONNECTING, 0K4 .

-- If the Battery, 48 V -A6- was replaced, the new Battery, 48 V -A6- must be adapted.

Procedure 

-- Connect the Vehicle Diagnostic Tester.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.