PROTECTIVE HOUSING FOR Battery, 48 V -A6-, REMOVING AND INSTALLING: Removing
-- Remove the Battery, 48 V -A6-. Refer to Battery, 48 V -A6-, REMOVING AND INSTALLING, 0K4 .
-- Remove the pressure equalization hose -1- by pressing the catches on both sides in direction of -arrows-.
-- Remove the screws -arrows-.
-- Remove the cover plate -2-.
-- Loosen the bolts -4- for the retaining bracket -5- four turns.
-- Remove the Battery, 48 V - A6- -3- from the protective housing -1-.
- Follow the disposal regulations for batteries when disposing of them. Refer to Battery .