LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2022 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 40 (Interior Lights, Switches) >> 96 Interior Lights, Switches >> Lane Change Assistance >> Lane Change Assistance, Calibrating

Lane Change Assistance, Calibrating

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

Conditions

-- The Lane Change Assistance Control Module -J769- /Lane Change Assistance Control Module 2 -J770- must be calibrated. Refer to Vehicle Diagnostic Tester during the following conditions:

Preparing for Calibration

GWWA96-11470Courtesy of AUDI OF AMERICA, LLC
  1. : VAS6350/2 
    • For distance measurement
    • Usage information. Refer to the : VAS6350  Owner's Manual.
  2. : VAS6350A 
  3. Level
    • On the : VAS6350A 
    • To check the horizontal position of the : VAS6350A 
  4. Catch Bracket
    • To mount the : VAS6350/2  for the distance measurement
    • Distance to the : VAS6350/1  on the rear wheels: dimension -a- = 1700 ± 2 mm
  5. : VAS6350/4 
    • Is moved from one side of the measuring field to the other during calibration
    • When installed correctly, the vehicle electrical system voltage line must be connected at lower left of the calibration device (as seen in direction of travel)
  6. Brand Emblem
    • The laser point is aligned to the center of the brand emblem
  7. : VAS6350/1 
    • With wheel bolt adapter and measuring paddle
  8. Measuring Scale
    • For positioning the : VAS6350/4 
  9. : VAS6350/3 
    • With "laser protective eyewear"
    • On the : VAS6350A 
    • Switching on and off. Refer to : VAS6350  Owner's Manual.
  10. Plastic Foot
    • Can be adjusted when setting the horizontal position of the : VAS6350A 
    • Quantity: 3

Preliminary Work

-- Move the vehicle onto a solid, flat surface.

-- Activate the "standard vehicle height" on vehicles with air suspension (MMI setting: automatic or comfort).

-- Apply the parking brake - the vehicle must not move during the measurement.

-- Place the front wheels in a straight-ahead position - steering wheel in neutral position.

-- Connect the Vehicle Diagnostic Tester.

TIP:

If a malfunction message appears in the display. Refer to the Vehicle Diagnostic Tester Operating Instructions.

-- Switch the ignition on.

-- Remove the label with the metal foil from the bumper cover, if necessary.

-- Secure three suitable wheel bolt adapters for the wheel bolts on each : VAS6350/1  .

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC

-- Insert the measuring paddle at both : VAS6350/1  and secure with the locking nut.

-- Place the : VAS6350/1  onto the wheel bolts on both rear wheels.

-- Place the : VAS6350/1  on the wheels so that the "anti-theft wheel bolts" are not connected to the wheel center mounting.

-- Adjust the measuring paddle using the locking nuts so that they move freely just above the floor.

-- Position the : VAS6350A  at distance -a- to the rear wheels.

Fig 2: Positioning Calibration Device VAS 6350
GWWA96-10536Courtesy of AUDI OF AMERICA, LLC

-- Switch on the : VAS6350/2  with the ON  button.

Fig 3: Identifying Laser Display
GWWN94-10681Courtesy of AUDI OF AMERICA, LLC

Display on the : VAS6350/2  :

-- For distance measurement, hold the : VAS6350/2  -2- flush to the left catch bracket as shown.

Fig 4: Holding Distance Laser VAS 6350/2 Flush To Catch Bracket
GWWA96-10535Courtesy of AUDI OF AMERICA, LLC

-- Make sure the "laser beam" for the distance measurement contacts the enlarged lower part on the paddle -1-.

If this is not the case, measuring paddle height must be corrected using locking nuts on : VAS6350/1  .

-- Briefly press the ON  button for distance measurement.

Fig 5: Identifying Display On VAS 6350/2
GWWA96-10289Courtesy of AUDI OF AMERICA, LLC

Display on the : VAS6350/2  :

-- Repeat the measuring procedure from the right stop bracket to the right rear wheel.

If both measured values are not the same, adjust the : VAS6350A  accordingly.

Calibrating Procedure

The Vehicle Diagnostic Tester is connected.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

TIP:

-- Secure the : VAS6350/4  to the : VAS6350A  mount on the rear left.

GWWA96-11376Courtesy of AUDI OF AMERICA, LLC

Dimension -a- is measured from the upper edge of the calibration device to the floor.

Model A5 Coupe/Sportback/Cabriolet
Adjustment dimension height in mm dimension -a- 800

-- The indicator on the base of the : VAS6350/4  must align with adjustment dimension on the measuring scale -1- on measuring field -arrow-.

Model A5 Coupe/Sportback/Cabriolet
Left adjustment dimension read in mm on the measuring scale -1- 716

-- Connect the : VAS6350/4  to the vehicle electrical system voltage.

-- Bring the : VAS6350A  into a horizontal position by turning the plastic feet.

Fig 6: Identifying Bubble Level (Sight Glass) On Calibration Tool VAS 6350
GWWN94-10686Courtesy of AUDI OF AMERICA, LLC

-- Turn on the : VAS6350/3A  on the : VAS6350A  .

GWWA96-11453Courtesy of AUDI OF AMERICA, LLC

-- Wear "laser protective eyewear".

-- Align the : VAS6350A  so that the : VAS6350/3  strikes the center of the brand emblem on the rear lid.

-- Check the distance on the left and right sides between the catch brackets of the : VAS6350A  and the measuring paddles -1- on wheel mountings again.

Fig 7: Holding Distance Laser VAS 6350/2 Flush To Catch Bracket
GWWA96-10535Courtesy of AUDI OF AMERICA, LLC

Calibration Procedure

The following should not occur during the calibration procedure:

Procedure 

Fig 8: Identifying Assistance Calibration Device VAS 6350/4 Components
GWWA96-10358Courtesy of AUDI OF AMERICA, LLC

-- Turn on the : VAS6350/4  at the power switch -3-.

-- If the red LED -2- turns on: check the : VAS6350/4  .

-- Follow the instructions in the Vehicle Diagnostic Tester display.

During the program sequence, there is a prompt to switch the : VAS6350/4  from the left to the right side of the : VAS6350A  .

GWWA96-11375Courtesy of AUDI OF AMERICA, LLC

-- Turn off the : VAS6350/4  and reposition the calibration tool.

Dimension -a- is measured from the upper edge of the calibration device to the floor.

Model A5 Coupe/Sportback/Cabriolet
Adjustment dimension height in mm dimension -a- 800

-- The indicator on the base of the : VAS6350/4  must align with adjustment dimension on the measuring scale -1- on measuring field -arrow-.

Model A5 Coupe/Sportback/Cabriolet
Right adjustment dimension read in mm on the measuring scale -1- 716

-- Turn on the : VAS6350/4  at the power switch -3-.

Fig 9: Identifying Assistance Calibration Device VAS 6350/4 Components
GWWA96-10358Courtesy of AUDI OF AMERICA, LLC

-- Follow the instructions in the vehicle diagnostic tester display.

-- After calibrating the lane change assistance successfully, end "calibration", switch off the ignition and disconnect the diagnostic connector.