Home >> Audi >> 2022 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 29 (Charging System (Battery, Starter And Generator) & Cruise Control (1 Of 2)) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Battery, 48 V -A6-, Visually Inspecting And Classifying

Battery, 48 V -A6-, Visually Inspecting And Classifying

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

Procedure 

CAUTION:

There is danger of a health risk due to poisonous dust and fluids.

- Never work on a lithium-ion battery with a short circuit.

CAUTION:

There is a risk of burns due to a hot lithium-ion battery.

It is possible to burn hands.

- Do not touch a hot battery.

- Wear safety gloves.

The Battery, 48 V -A6- must be checked for:

-- After the visual inspection, the Battery, 48 V -A6- must be classified.

-- Connect the Vehicle Diagnostic Tester.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.