Possible Deviation From Specified Value During The Pressure Test (2 Of 9)
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2022 Audi S5, 2022 Audi RS 5, 2021 Audi S5, 2021 Audi RS 5, and 2021 Audi A5 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
| Possible Deviation from Specified Value During the Pressure Test |
|---|
|
| Possible causes for the deviation from specified value and their solutions |
|
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to MECHANICALLY DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
NOTE:
Check the measured values of the Evaporator Vent Temperature Sensor -G263- and the activation of the A/C Compressor Regulator Valve -N280-. If the measured value of the Evaporator Vent Temperature Sensor -G263- malfunctions the evaporator can ice over or the cooling output is not reached. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding" function of the A/C system.
If the A/C system function is not OK after repeating the test, for example after replacing expansion valve, clean the refrigerant circuit by flushing using the refrigerant R1234yf. Refer to REFRIGERANT CIRCUIT, CLEANING . Then replace the A/C compressor and reservoir/receiver/dryer (or dryer cartridge). Refer to Refrigerant Circuit .