LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2022 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 86 (Air Conditioning (Refrigerant R1234YF Servicing) (1 Of 2)) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Container For Analysis, Processing, Or Disposal >> Recycling Container, Filling With Contaminated Refrigerant Using Extractor:Vas581007

Recycling Container, Filling With Contaminated Refrigerant Using Extractor:Vas581007

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2022 Audi S5, 2022 Audi RS 5, 2021 Audi S5, 2021 Audi RS 5, and 2021 Audi A5 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

CAUTION:

Risk of frostbite or suffocation due to dry ice.

Frostbite of the skin and other body and suffocation as a gas is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Only work with the dry ice in well-ventilated areas.

- Never perform procedures in and near basement staircases or other below ground areas.

CAUTION:

Risk of explosion due to improperly stored dry ice.

When dry ice evaporates the pressure in the container increases. Unsuitable containers can explode.

- Transport and store dry ice only in the containers designed for it.

Fill the refrigerant in a supercooled recycling bottle.

-- Remove the recycling bottle seal and remove the closure cap from the connection.

-- Connect the A/C Service Station to the recycling container. To do so remove the low pressure service coupling from the A/C Service Station filler hose and connect the filler hose directly with the adapter belonging to the Extractor :VAS581007  to the adapter on the recycling bottle.

-- Carefully open the recycling bottle hand shut-off valve to check the vacuum and check the vacuum in the bottle.

-- If necessary evacuate the recycling bottle using the A/C Service Station.

-- Close the recycling bottle hand shut-off valves.

-- Switch off the ignition.

-- For good ventilation of the work space switch on the workshop ventilation equipment if equipped.

CAUTION:

There is a risk of explosion due to overfilling refrigerant canisters.

Refrigerant can expand and the refrigerant canister can explode due to overfilling.

- Use a refrigerant canister with safety valve.

- Never exceed the permitted capacity of the refrigerant canister.

CAUTION:

Chemical reaction due to contaminated refrigerant. When mixing gases of unknown composition different chemical reactions can occur.

Injury is possible.

- Never mix refrigerant of different origins.

-- Connect the service coupling for refrigerant R1234yf -5- to the filler hose -4-.

GWWA87-12270Courtesy of AUDI OF AMERICA, LLC

-- Connect the filler hose -4- with the connection piece -3- (and seal -2-) on the recycling bottle -1-.

-- Position the spacer -6- in the insulated container -7-.

-- Cover the bottom of the insulated container -7- with dry ice.

-- Position the recycling bottle -1- in the insulated container -7-.

-- Fill the remaining dry ice in the insulated container -7-.

-- Cool the recycling bottle -1- with dry ice (approximately 15 minutes).

-- Connect the recycling container -1- via the service coupling -5- on the vehicle refrigerant circuit.

-- Open the recycling bottle hand shut-off valve -1-.

-- Connect the pressure gauge to the refrigerant circuit (or the use the A/C Service Station pressure gauge) and check the refrigerant circuit pressure.

-- Carefully open the service coupling -5- on the filler hose to the recycling bottle and let the refrigerant flow slowly in the recycling bottle -1-.

-- Wait until the refrigerant in the recycling bottle -1- is liquid (pay attention to the pressure indicator on the connected pressure gauge).

-- Close the service coupling -5- and the recycling bottle hand shut-off valve -1-.

-- Remove the filler hose -4- and connection piece -3- from the recycling bottle -1- and close the recycling bottle connection with the closure cap.

-- Place the insulated container -7- with the recycling bottle -1- and the dry ice in a secured, well ventilated area outside of the building.

-- Open the cover of the insulated container -7- or remove and let the dry ice completely evaporate.

CAUTION:

Risk of damaging the recycling container due to impact.

- Remove the recycling bottle first from the insulated container, when the dry ice is evaporated and the recycling bottle has taken the ambient temperature.

-- Remove the recycling bottle -1- from the insulated container -7-.

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .

-- Fill out the supplement data sheet for the recycling bottle with contaminated refrigerant and secure on the recycling bottle.

-- Return the filled recycling bottle using the method of delivery for the recycling bottle, while paying attention to the applicable laws.