After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, 2.9L ENGINE: Removing
WARNING: This page is about a different car, the 2021 Audi S5 Sportback and 2020 Audi S5 Sportback. However, it is still accessible from the selected car via links, so may be relevant.
-- Remove the right catalytic converter (refer to CATALYTIC CONVERTER, REMOVING AND INSTALLING ) move with the heated oxygen sensor connected to the side and secure, to do so free up the wire.
-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING, 2.9L ENGINE .
-- Remove the double bolt -2- and bolts -1- and remove the bracket for the After-Run Coolant Pump -V51-.
-- Disconnect the connector -3-.
-- Tighten the bolt -arrow- using the : T10405 .
-- Loosen the hose clamp -1- and remove the After-Run Coolant Pump -V51- -2-.