LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2022 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 194 (Air Conditioning (Refrigerant R1234YF Servicing) (Tools & Testing)) >> 87 Air Conditioning >> Working With A/C Service Station >> Pressures, Checking >> Electrically-Driven A/C Compressor, Checking Pressure With A/C System Switched On >> Possible Deviation From Specified Value During The Pressure Test (6 Of 11)

Possible Deviation From Specified Value During The Pressure Test (6 Of 11)

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2022 Audi S5 Sportback, 2022 Audi RS 5 Sportback, 2022 Audi A5 Sportback, 2021 Audi S5 Sportback, and 2021 Audi RS 5 Sportback. However, it is still accessible from the selected car via links, so may be relevant.
Possible Deviation from Specified Value during the Pressure Test
  • The required cooling output is not attained in the heater and A/C unit evaporator (and in the evaporator for battery cooling).
  • The high pressure pipe corresponds to the specified value
  • The low pressure corresponds to the specified value or is too low
Possible causes for the deviation from specified value and their solutions
  • The activation of the A/C compressor and if equipped the refrigerant shut-off valve 1 the refrigerant shut-off valve 2 is faulty. Use the Vehicle Diagnostic Tester in the "Guided Fault Finding"  function for the A/C system and the battery regulation.
-- Check the activation and function of the A/C compressor (and if equipped the refrigerant shut-off valve 1 and the refrigerant shut-off valve 2) and if necessary service. Use the Vehicle Diagnostic Tester in the "Guided Fault Finding"  function of the A/C compressor and the battery regulation. If this is OK extract refrigerant from the refrigerant circuit.
  • There is too little refrigerant in the refrigerant circuit.
-- Extract refrigerant from the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING .-- If the extracted refrigerant quantity is significantly less than the specified capacity (more that 100 g (3.5 oz)). Refer to Technical Data , and look for leaks and correct. Refer to LEAKS, FINDING .-- If the extracted refrigerant quantity corresponds to the specified capacity or is only slightly smaller (less than 100 g (3.5 oz)). Refer to Technical Data and Technical Data . Check the refrigerant shut-off valve for function. Refer to the Refrigerant Circuit .
  • The expansion valve for the evaporator in the heater and A/C unit is faulty. Refer to Refrigerant Circuit .
  • A refrigerant shut-off valve is faulty (closed). Use the Vehicle Diagnostic Tester in the "Guided Fault Finding"  function for the A/C system and the battery regulation. Refer to Refrigerant Circuit .
-- If equipped check the function of the installed shut-off valve. Refer to Refrigerant Circuit .-- Replace the expansion valve for the evaporator in the heater and A/C unit. Refer to Refrigerant Circuit .
  • Too much refrigerant oil in the refrigerant circuit
-- Clean the refrigerant circuit (flush with refrigerant R1234yf). Refer to REFRIGERANT CIRCUIT, CLEANING .-- Replace the expansion valve for the evaporator in the A/C unit (and for the evaporator for battery cooling) as well as the desiccant bag/dryer cartridge (or receiver/receiver/dryer). Refer to COMPONENTS, REPLACING and Refrigerant Circuit .
Final Procedures
-- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to ELECTRICALLY-DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON .