Coolant Shut-Off Valve -N82-, Removing And Installing: Installing
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2022 Audi S5 Sportback, 2022 Audi RS 5 Sportback, 2022 Audi A5 Sportback, 2021 Audi S5 Sportback, and 2021 Audi RS 5 Sportback. However, it is still accessible from the selected car via links, so may be relevant.
Install in reverse order of removal. Note the following.
TIP
- Since only a small amount of coolant flowed out of the coolant circuit when removing the Coolant Shut-Off Valve -N82- as described above, the coolant flows into Coolant Shut-Off Valve -N82- after installing and removing the hose clamps (additionally opening the coolant expansion tank cap).
- The shut-off valve -A- is secured to the noise insulation via the rubber bushing -L- (with bearing bushings and washers) the nuts -G- and the bolts -F- on the bracket -K-.
-- Check the rubber bushing -L- is seated correctly in the bracket -K-.
-- Villa and bleed the coolant circuit. Refer to COOLANT CIRCUIT, BLEEDING .
Tightening Specification
| Component | Tightening Specification |
|---|---|
| Coolant Shut-Off Valve -N82- on the bracket | 8 Nm |
| Bracket for the Coolant Shut-Off Valve -N82- on the plenum chamber | 8 Nm |