Home >> Audi >> 2022 >> A5 Quattro Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 134 (Cooling System [CWGD,DECA] [Cabriolet]) >> 19 Cooling System >> Coolant System/Coolant >> Coolant, Draining And Filling >> Coolant, Draining And Filling, 2.9L Engine >> Coolant, Filling

Coolant, Filling

WARNING: This page is about a different car, the 2022 Audi S5, 2022 Audi RS 5, 2021 Audi S5, 2021 Audi RS 5, and 2020 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.
GWWN19-11197Courtesy of AUDI OF AMERICA, LLC

-- Fill the coolant reservoir from the : VAS6096  with 10 liters (10.56 quarts) of coolant with the correct mixture ratio. Refer to Coolant Mixture Ratio  for the mixture ratio.

-- To make the filling procedure easier position the coolant reservoir as high up as possible for example on a vehicle jack or the engine and the transmission.

-- Install the : VAG1274/8  on the coolant expansion tank.

-- Attach the : VAS6096  on the : VAG1274/8  .

-- Place the drain hose -2- in a small container -3-.

TIP:

A small amount of coolant which should be collected is drawn off with the discharged air.

-- Close the valves -A and B- by turning lever at a right angle to the flow direction.

-- Connect the hose -4- to compressed air.

-- Open the valve -B- by turning the lever in the flow direction.

GWWN19-11198Courtesy of AUDI OF AMERICA, LLC

-- Briefly open the valve -A- by turning the lever in the flow direction so that the hose on the : VAS6096  coolant reservoir fills with coolant.

-- Close the valve -A- again.

-- Leave the valve -B- open another two minutes.

-- Close the valve -B-.

-- Remove the pressure hose.

-- Open the valve -A-.

-- Remove the : VAS6096  from the : VAG1274/8  on coolant expansion tank.

-- Connect the : VAG1274/10  to the : VAG1274/8  .

GWWA19-12247Courtesy of AUDI OF AMERICA, LLC

-- Fill with coolant until the cooling system tester tube is full. Fill again during the bleeding procedure if required.

Bleed Cooling System.

-- Remove the lock carrier cover. Refer to LOCK CARRIER COVER, REMOVING AND INSTALLING .

-- Place a cloth underneath to catch any escaping coolant.

GWWA19-12721Courtesy of AUDI OF AMERICA, LLC

-- Open the bleeder screw -arrow- until coolant starts to come out.

-- Close the bleeder screw.

-- Place a cloth underneath to catch any escaping coolant.

GWWA19-12722Courtesy of AUDI OF AMERICA, LLC

-- Open the bleeder screw -arrow- until coolant starts to come out.

-- Close the bleeder screw.

-- Tighten the cap on the coolant expansion tank until it locks into place.

-- If the vehicle has a parking/auxiliary heater, switch it on for about 30 seconds.

-- Connect the Vehicle Diagnostic Tester.

-- Start the program 01 Coolant Circuit Bleeding  using the Vehicle Diagnostic Tester and follow the instructions in the vehicle diagnostic tester display.