Instrument Cluster, Setting Sri And Mileage
Special tools and workshop equipment required
- Fault Read Out Device: VAG1551
Instrument cluster must be coded before setting if it was replaced.
-- Press button 1 to select "Rapid data transfer" operating mode 1.
Indicated on display
| Rapid data transfer HELP Insert address word XX |
-- Press buttons 1 and 7 to insert "Instrument Cluster" address word 17.
Indicated on display
| Rapid data transfer Q 17 - Instrument Cluster |
-- Press Q button to confirm input.
Indicated on display
| Rapid data transfer Scan Tool sends address word 17 |
After 5 seconds the display indicates a part number and the control module code.
| 4D0 919 033 C4 Instrument cluster D03 → Coding 00262 WSC 06812 |
-- Press → button.
Indicated on display
| Rapid data transfer Q Select function XX |
-- Press buttons 1 and 0 to select "Adaptation" function 10.
Indicated on display
| Rapid data transfer Q 10 - Adaptation |
-- Press Q button to confirm input.
Indicated on display
| Adaptation Insert channel number XX |
SRI, oil change indicator, resetting (distance)
Setting of service interval display must be done in kilometers. Therefore calculate the value from miles to kilometers. Multiply miles by 1.6 to convert to km.
Adaptation number is for example only table on INSTRUMENT CLUSTER
-- Press buttons 0 and 5 to select channel 5.
-- Press Q button to confirm input.
Indicated on display
| Channel 5 Adaptation 15 → ← 1 3 → |
-- Advance through program with → button.
Indicated on display
| Channel 5 Adaptation 15 Q Input adaptation value XXXXX |
-- +Input 5 digit adaptation value between 0 km (00000) and 15000 km (00015).
The value can be entered in steps of 1000 km
Example: 7500 mi/12000 km, therefore enter 00012.
Indicated on display
| Channel 5 Adaptation 15 Q Input adaptation value 00012 |
-- Press Q button to confirm input.
Indicated on display
| Channel 5 Adaptation 12 Q ← 1 3 → |
-- Press Q button to confirm input.
Indicated on display
| Channel 5 Adaptation 12 Q Store changed value? |
-- Press Q button to confirm input.
Indicated on display
| Channel 5 Adaptation 12 → Changed value is stored |
-- Press → button to end coding.
Indicated on display
| Rapid data transfer HELP Select function XX |
-- Press buttons 1 and 0 to select "Adaptation" function 10.
Indicated on display
| Rapid data transfer Q 10 - Adaptation |
-- Press Q button to confirm input.
Indicated on display
| Adaptation Insert channel number XX |
SRI, inspection indicator (In 1), resetting (distance)
Setting of service interval display must be done in kilometers. Therefore calculate the value from miles to kilometers. Multiply miles by 1.6 to convert to km.
-- Press buttons 0 and 6 to select channel 6.
-- Press Q button to confirm input.
Indicated on display
| Channel 6 Adaptation 30 → ← 1 3 → |
-- Press → button to advance through program sequence.
Indicated on display
| Channel 6 Adaptation 30 Q Input adaptation value XXXXX |
-- Enter value between 0 km (00000) and 30000 km (00030).
The value can be entered in steps of 1000 km.
Example: 15000 mi/24000 km, therefore enter 00024.
-- Press Q button to confirm input.
Indicated on display
| Channel 6 Adaptation 24 Q ← 1 3 → |
-- Press Q button to confirm input.
Indicated on display
| Channel 6 Adaptation 24 Q Store changed value? |
-- Press Q button to confirm input.
Indicated on display
| Channel 6 Adaptation 24 → Changed value is stored |
-- Press → button to end coding.
Indicated on display
| Rapid data transfer HELP Select function XX |
-- Press buttons 1 and 0 to select "Adaptation" function 10.
Indicated on display
| Rapid data transfer Q 10 - Adaptation |
-- Press Q button to confirm input.
Indicated on display
| Adaptation Insert channel number XX |
SRI, inspection indicator (In 1), resetting (time)
-- Press button 0 and 7 to select channel 7.
-- Press Q button to confirm input.
Indicated on display
| Channel 7 Adaptation 36 → ← 1 3 → |
-- Advance through program sequence with → button.
Indicated on display
| Channel 7 Adaptation 36 Q Input adaptation value XXXXX |
-- Enter adaptation value between 0 days (00000) and 360 days (00036). The value can be entered in steps of 10 days. Example: 360 days, therefore enter 00036.
Inspection table INSTRUMENT CLUSTER
-- Press Q button to confirm input.
Indicated on display
| Channel 7 Adaptation 36 Q ← 1 3 → |
-- Press Q button to confirm input.
Indicated on display
| Channel 7 Adaptation 36 Q Store changed value? |
-- Press Q button to confirm input.
Indicated on display
| Channel 7 Adaptation 36 → Changed value is stored |
-- Press → button to end coding.
Indicated on display
| Rapid data transfer HELP Select function XX |
-- Press buttons 1 and 0 to select "Adaptation" function 10.
Indicated on display
| Rapid data transfer Q 10 - Adaptation |
-- Press Q button to confirm input.
Indicated on display
| Adaptation Insert channel number XX |
SRI, inspection indicator (In 2), resetting (time)
-- Press button 0 and 8 to select channel 8.
-- Press Q button to confirm input.
Indicated on display
| Channel 8 Adaptation 66 → ← 1 3 → |
-- Advance through program sequence with → button.
Indicated on display
| Channel 8 Adaptation 66 Q Input adaptation value XXXXX |
-- Enter Adaptation value between 0 days (00000) and 730 days (00073). The value can be entered in steps of 10 days. Example: 730 days, therefore enter 00073.
-- Press Q button to confirm input.
Indicated on display
| Channel 8 Adaptation 73 Q Store changed value? |
-- Press Q button to confirm input.
Indicated on display
| Channel 8 Adaptation 73 Q Changed value stored |
-- Press → button to end coding.
Indicated on display
| Rapid data transfer HELP Select function XX |
-- Press buttons 1 and 0 to select "Adaptation" function 10.
Indicated on display
| Rapid data transfer Q 10 - Adaptation |
-- Press Q button to confirm input.
Indicated on display
| Adaptation Insert channel number XX |