Instrument Cluster Mileage Display, Setting

Special tools and workshop equipment required 

CAUTION:
  • This setting is only possible with a new cluster
  • This setting is possible only one time for each instrument cluster.
  • Only a larger setting value can be entered.
  • If the wrong information has been entered and confirmed; correction is not possible. The instrument cluster must be replaced.
NOTE:

Setting of service interval display must be done in kilometers. Therefore calculate the value from miles to km. Multiply miles by 1.6 to convert to km.

-- Press buttons and "Login-Procedure" function 11.

Indicated on display

Rapid data transfer Q 
11 - Login-Procedure 

-- Press button to confirm input.

Indicated on display

Login-Procedure 
Enter code number XXXXX 

-- Input code number 13861.

-- Press button to confirm input.

Indicated on display

Rapid data transfer HELP 
Select function XXXXX 

-- Press buttons and to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q 
10 - Adaptation 

-- Press button to confirm input.

Indicated on display

Channel number entered XX 

-- Press button and to select channel 9.

-- Press button to confirm input.

Indicated on display

Channel 9 Adaptation 2 → 
← 1 3 → 

-- Advance through program sequence with →  button.

Indicated on display

Channel 9 Adaptation 2 Q 
XXXXX 

-- Enter adaptation value.

Example:

Kilometer status = 89627; adaptation value = 08963

-- Round ones value up to the next tens and drop ones place (627 becomes 630; drop zero).

-- Add zero in hundred-thousands place.

Ones: round to the next tens

X         Hundred thousands: 100000 - 900000 km
  X       Ten thousands: 10000 - 90000 km
    X     Thousands: 1000 - 9000 km
      X   Hundreds: 100 - 900 km
        X Tens: 10 - 90 km

-- Press button to confirm input.

Indicated on display

Channel 9 Adaptation 2 Q 
← 1 3 → 

-- Press button to confirm input.

Indicated on display

Channel 9 Adaptation 2 Q 
Store revised value? 

-- Press button to confirm input.

Indicated on display

Channel 9 Adaptation 2 
Changed values stored 

-- Press →  button to end coding.

Indicated on display

Rapid data transfer HELP 
Select function XX 

-- Press button and "End Output" function 06.

Indicated on display

Rapid Data Transfer Q 
06 - End Output 

-- Press button to confirm input.