Charge Air Pressure Sensor 2 -G447-, REMOVING AND INSTALLING: Installing
Install in reverse order of removal and note the following:
- Replace the O-ring after removing.
- Secure all hose connections with hose clamps that match the ones used in series production.
-- Install the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .