LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2021 >> Q5 e Premium >> Repair and Diagnosis >> External Pages >> Different car >> Section 342 (Cooling System (4-Cylinder Direct Injection 2.0L 4V TFSI Engine (Ea 888EVO4)) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> After-Run Coolant Pump -V51-, REMOVING AND INSTALLING >> After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, AUDI Q7/Q8 >> Removing

After-Run Coolant Pump -V51-, REMOVING AND INSTALLING, AUDI Q7/Q8: Removing

WARNING: This page is about a different car, the 2024 Audi Q7 and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the rear noise insulation. Refer to NOISE INSULATION, REMOVING AND INSTALLING .

-- If installed, remove the heat shield boot.

GWWN19-11495Courtesy of AUDI

-- Disconnect the connector -1-.

-- Place a cloth underneath to catch any escaping coolant.

-- Loosen the hose clamps -2-, then clamp off the coolant hoses with the Hose Clamps - Up To 25mm:3094  and remove them.

-- Remove the bolts -arrows- and the Recirculation Pump -V55-.

-- Remove the pump from the bracket.