Thermal Management Coolant Temperature Sensor 6 -G907-, REMOVING AND INSTALLING
Procedure
- High-voltage system cold.
-- To remove any residual pressure in the cooling system, cut the seal tab -3- and open the coolant expansion tank cap -1- for the high-voltage system cooling circuit.
-- Disconnect the connector -1-.
-- Remove the bolt -2-, and remove the Thermal Management Coolant Temperature Sensor 6 -G907-.
- Replace the O-rings after removing them.
-- To prevent coolant loss, install the new coolant temperature sensor immediately.
-- Add coolant. Refer to COOLANT, ADDING AND BLEEDING COOLING SYSTEM, VEHICLE WITH HIGH-VOLTAGE SYSTEM, HIGH-VOLTAGE SYSTEM COOLANT CIRCUIT .
Tightening Specifications