LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Cooling Systems >> Cooling System (8-Cylinder Direct Injection 4.0L 4V TFSI Engine Ea825) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Electric Coolant Pump, Removing And Installing >> Coolant Recirculation Pump -V50-, REMOVING AND INSTALLING >> Removing

Coolant Recirculation Pump -V50-, REMOVING AND INSTALLING: Removing

-- Remove the front right wheel housing liner front section. Refer to OVERVIEW - FRONT WHEEL HOUSING LINER .

-- Disconnect the connector -2-.

GWWA19-12205Courtesy of AUDI OF AMERICA, LLC

-- Place a cloth underneath to catch any escaping coolant.

-- Disconnect and remove the coolant hoses with Hose Clamps - Up To 25mm:3094  , to do this, loosen the hose clamps -1-.

-- Remove the bolts -3- and remove the coolant pump.