LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit >> General Description - Refrigerant Circuit Components >> Condenser

General Description - Refrigerant Circuit Components: Condenser

NOTE:

Depending on the refrigerant circuit design, the receiver/dryer is installed (integrated) either on the condenser or inside the condenser. Refer to Air Conditioning (1 Of 3) / Air Conditioning (3 Of 3) (vehicle-specific Service Information) and the Parts Information.

The condenser is available in different versions and can be differentiated only by the part number on the outside. For version -1-, the condenser is divided into two areas "2 way condenser". For version -2-, the condenser is divided into four areas "4 way condenser".

Fig 1: Identifying Condenser With Fluid Reservoir Installed
GWWA87-11519Courtesy of AUDI OF AMERICA, LLC

This illustration shows a condenser with the receiver/dryer -C- installed.

The gaseous refrigerant enters at the connection -A- into the condenser. The refrigerant is then cooled inside the condenser and becomes fluid.

The liquid refrigerant collects in the receiver/dryer -C- (with dryer) and flows through the lower cooling area towards the connection -B-.

Depending on the design of the condenser (interior volumes, delivery flow, etc.), the refrigerant capacity in a refrigerant circuit may vary. For this reason always pay attention to the correct version and allocation of the condenser. Refer to Technical Data (vehicle-specific Service Information) and the Parts Information.