Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (2 Of 3) >> 87 Air Conditioning >> Front Heater And A/C Unit >> Fresh Air Blower -V2- WITH Fresh Air Blower Control Module -J126-, REMOVING AND INSTALLING >> Removing

Fresh Air Blower -V2- WITH Fresh Air Blower Control Module -J126-, REMOVING AND INSTALLING: Removing

-- On vehicles with high-voltage system, switch on the "parking air conditioner" function (deactivate). Refer to the Owner's Manual.

-- Position the front passenger seat as far back as possible.

-- Switch off the ignition.

-- Remove the glove compartment. Refer to GLOVE COMPARTMENT, REMOVING AND INSTALLING .

-- Remove the footwell vent on the front passenger side. Refer to FRONT PASSENGER SIDE FOOTWELL VENT, REMOVING AND INSTALLING .

-- Release the connector -A- and disconnect from the Fresh Air Blower -V2- (with the Fresh Air Blower Control Module -J126-) -C-.

GWWA87-11823Courtesy of AUDI OF AMERICA, LLC

-- Remove the insulation -B-.

-- Remove the bolts -A-.

GWWA87-11824Courtesy of AUDI OF AMERICA, LLC
CAUTION:

There is a risk of burns from the hot radiating surface of the fresh air blower control module.

It is possible to burn hands.

- Wear safety gloves.

CAUTION:

Risk of damaging the fresh air blower if operated incorrectly.

Imbalance and problems during operation is possible.

- Avoid using force on the fan wheel.

- Never move the balancing weight on the fan wheel.

-- Remove the Fresh Air Blower -V2- (with the Fresh Air Blower Control Module -J126-) -B- carefully from air intake manifold -C-.