Plenum Chamber Water Drain, Cleaning
Procedure
-- On vehicles with high-voltage system, switch on the "parking air conditioner" function (deactivate). Refer to the Owner's Manual.
-- Switch off the ignition.
-- Remove the plenum chamber cover -A-. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .
-- Clean debris (leaves, pine tree needles) and other contamination out of plenum channel -A-.
-- Check the valves -C- of the water drains -B- for proper functioning (valves -C- must not stick or be obstructed by dirt).
TIP
- To check the water drains -B- that are difficult to reach, use a commercially available and illuminated endoscope, for example. It is best to use a version that has a flexible waterproof head.
- Use a commercially available flexible gripping tool to clean, for example coarse dirt from difficult to reach water drains -B-. Then clean the remaining dirt through the valves -C-.