Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (2 Of 3) >> 87 Air Conditioning >> Air Routing >> Plenum Chamber Water Drain, Cleaning

Plenum Chamber Water Drain, Cleaning

Procedure 

GWWA87-11862Courtesy of AUDI OF AMERICA, LLC

-- On vehicles with high-voltage system, switch on the "parking air conditioner" function (deactivate). Refer to the Owner's Manual.

-- Switch off the ignition.

-- Remove the plenum chamber cover -A-. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

-- Clean debris (leaves, pine tree needles) and other contamination out of plenum channel -A-.

-- Check the valves -C- of the water drains -B- for proper functioning (valves -C- must not stick or be obstructed by dirt).

GWWA87-12584Courtesy of AUDI OF AMERICA, LLC

TIP