A/C System Particulate Matter Concentration Sensor -G930-, REMOVING AND INSTALLING: Removing
-- Remove the glove compartment. Refer to GLOVE COMPARTMENT, REMOVING AND INSTALLING .
-- Remove the screw clips -A-.
-- Loosen the footwell cover -B- from the heater and A/C unit air intake manifold and remove.
-- Release and disconnect the connector -C-.
-- Remove the bolts -A-.
-- Release the retainers -B- and move the sensor -D- to the side.
-- Release the retainer -arrow- and disengage the connection -E-.
-- Remove the sensor -D-.