LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (2 Of 3) >> 87 Air Conditioning >> Air Ionization >> A/C System Particulate Matter Concentration Sensor -G930-, REMOVING AND INSTALLING >> Removing

A/C System Particulate Matter Concentration Sensor -G930-, REMOVING AND INSTALLING: Removing

-- Remove the glove compartment. Refer to GLOVE COMPARTMENT, REMOVING AND INSTALLING .

-- Remove the screw clips -A-.

GWWA87-11821Courtesy of AUDI OF AMERICA, LLC

-- Loosen the footwell cover -B- from the heater and A/C unit air intake manifold and remove.

-- Release and disconnect the connector -C-.

GWWA87-12402Courtesy of AUDI OF AMERICA, LLC

-- Remove the bolts -A-.

-- Release the retainers -B- and move the sensor -D- to the side.

-- Release the retainer -arrow- and disengage the connection -E-.

-- Remove the sensor -D-.