Evacuating And Charging Valve, Removing And Installing, Low And High Pressure Side: Installing

Install in reverse order of removal and note the following:

-- Evacuate and charge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .

-- Switch the ignition on.

-- On vehicles with a high-voltage system (Audi Q7 e-tron), initiate the basic setting of the A/C system through the Thermal Management Control Module -J1024- and activate the power-controlled valves using one of the routines stored there. "Charge/flush the refrigerant circuit stop routine" using the Vehicle Diagnostic Tester in the "Guided Fault Finding"  function.

-- Then check the DTC memory of the Thermal Management Control Module -J1024- (on vehicles with high-voltage system) and of the Front A/C Display Control Head -E87- and delete any entries displayed using the Vehicle Diagnostic Tester in the "Guided Fault Finding"  function.

-- Start the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .

-- Install the plenum chamber cover. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .