LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (1 Of 3) >> 87 Air Conditioning >> Adjustment Motors >> Recirculation Door Motor -V113-, REMOVING AND INSTALLING >> Removing

Recirculation Door Motor -V113-, REMOVING AND INSTALLING: Removing

GWWA87-11821Courtesy of AUDI OF AMERICA, LLC

-- On vehicles with high-voltage system, switch on the "parking air conditioner" function (deactivate). Refer to the Owner's Manual.

-- Position the front passenger seat as far back as possible.

-- Switch off the ignition.

-- Remove the fastening plug -A-.

-- Loosen the footwell cover -B- from the heater and A/C unit air intake manifold and remove.

-- Label the connector -C- and the actuator -B- (to avoid a mix up in case several connectors are disconnected at the same time).

GWWA87-11708Courtesy of AUDI OF AMERICA, LLC

-- Remove the bolts -A-.

-- Remove the actuator -B- from the door shaft -D-.

-- Release and disconnect the connector -C-.