Pressure Reservoir, Draining, AUDI Q7
Procedure
-- Connect the Vehicle Diagnostic Tester.
-- Switch the ignition on.
-- Select and start the Diagnostic operating mode.
-- Select the Test plan tab.
-- Select the Select individual test button and select the following tree structure consecutively:
- Suspension
- Suspension control
- 01 - OBD-capable systems
- 74 - Drivetrain Control Module J775
- 74 - Drivetrain Control Module Functions
- 74 - Basic setting
-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.
- Follow the guidelines for clean working conditions. Refer to GUIDELINES FOR CLEAN WORKING CONDITIONS .
-- Vent the system. Refer to AIR SUSPENSION SYSTEM, FILLING AND BLEEDING .
-- Switch off the ignition.
-- Remove the air duct to the vent from the B-pillar. Refer to OVERVIEW - B-PILLAR TRIM PANEL .
-- Slowly loosen air line -1- on pressure reservoir -2- and allow air pressure to come down. After the air pressure has escaped, remove the air line.
-- Remove and dispose of the pressure reservoir. Refer to PRESSURE RESERVOIR, REMOVING AND INSTALLING .
-- If the air line is removed from a component, check if the cutting ring is seated on the air line.