Refrigerant Expansion Valve 2 -N637-, REMOVING AND INSTALLING: Removing
- For all the following work, close the open lines and connections with clean plugs from the Engine Bung Set:VAS6122 .
-- Initiate the basic setting of the A/C system using the Thermal Management Control Module -J1024- and open the electric valves using the routine "Refrigerant Circuit, Extract, Evacuate and Fill" in the Vehicle Diagnostic Tester.
-- Switch off the ignition.
-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station .
-- Remove the plenum chamber bulkhead. Refer to PLENUM CHAMBER BULKHEAD, REMOVING AND INSTALLING .
Danger of frostbite due to refrigerant coming out under pressure.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- Evacuate or drain refrigerant and open the refrigerant circuit immediately.
- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit has not been opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.
-- Remove the bolts -3 and 7-.
-- Remove the bolts -5-.
-- Disconnect the connector -2- on the rear of the Refrigerant Expansion Valve 2 -N637- -1-.
-- Remove the refrigerant lines -4 and 6-.
-- Remove the expansion valve -1-.