Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 90 (Air Conditioning (Refrigerant R1234YF Tools & Testing Equipment)) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Cylinder For Analysis, Processing, Or Disposal >> RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS 581 011

RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS 581 011

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Audi SQ5, 2024 Audi Q5 e, 2024 Audi Q5, 2023 Audi SQ5, and 2023 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- Connect the Extraction Unit:VAS 581 011  according to the included Owner's Manual with the vehicle and the A/C Service Station R1234yf.

-- Fill the contaminated refrigerant using the Extraction Unit:VAS 581 011  in the recycling cylinder. Refer to the Owner's Manual.

-- Fill out the supplement data sheet for the recycling cylinder with contaminated refrigerant and secure on the recycling cylinder.

-- Return the filled recycling cylinder using the method of delivery for the recycling cylinder, while paying attention to the applicable laws.

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .