After-Run Coolant Pump -V51-, REMOVING AND INSTALLING: Removing
WARNING: This page is about a different car, the 2022 Audi Q8, 2021 Audi Q8, 2020 Audi Q8, and 2019 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .
-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING .
Vehicle without Parking Heater:
-- Lift the clamp -1- and remove the coolant hose.
-- Open the retainer in direction of -arrow- and push the Coolant Recirculation Pump -V50- to the side.
-- Remove the nuts -arrows- and remove the bracket -1- for the Coolant Recirculation Pump -V50-.
NOTE:
Ignore -2-.
Continuation for All Vehicles:
-- Remove the double bolts -2- and bolts -1- and remove the bracket for the After-Run Coolant Pump -V51-.
-- Release and disconnect the connector -3-.
-- Remove the bolt -arrow- using the :T10405 .
-- Loosen the hose clamp -1- and remove the After-Run Coolant Pump -V51- -2-.