GENERAL DESCRIPTION - Battery Charger:VAS5908

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Audi SQ5, 2024 Audi Q5 e, 2024 Audi Q5, 2023 Audi SQ5, and 2023 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

If software updates or flash campaigns/actions are performed on a vehicle, a charger with at least 70A charging current must be used in order to avoid problems during software updates and flash campaigns/actions.

Battery Charger "VAS 5903". Refer to Battery Charger .

Battery Charger "VAS5908". Refer to Battery Charger .

The Battery Charger:VAS5908  has the following modes available:

Technical Data

Replacement Parts

Refer to Battery Charger:VAS5908  Operating Instructions for more information.

Device Overview - Battery Charger:VAS5908 

GWWN27-11213Courtesy of AUDI

1 -  "ON/OFF" Voltage Switch

2 -  Power Supply Cable Connection

3 - ←  Up Button for Menu Selection

4 - ENTER  Button for Menu Selection or Starting

5 - ↓  Down Button for Menu Selection

6 -  Battery Charging Clamp Connection (Red Pliers)

7 -  Battery Charging Clamp Connection (Black Pliers)

8 -  Communication Interface RS232, 9-Pin

9 -  Signal Interface, 25-Pin

10 -  Menu Selection Display

11 -  LED Display for displaying operation and device status

LED Display -11-

The LED display on the front side of the device is to signal the operation and device status. The meaning of green, yellow, blinking red or illuminated LEDs in the different operating conditions is listed in a table. Refer to Battery Charger:VAS5908  Operating Information, 8) LED and remote indicator index.

Device Menu

Various parameters and default settings to ensure the measured values and the conditions for switching the Battery Charger:VAS5908  on and off can be set in the device menu.

-- Switch the Battery Charger:VAS5908  on.

-- With the ←↓  buttons, select the >>MENU<< line and confirm with the ENTER  button.

-- With the ←↓  buttons, select the >>DEVICE MENU<< line and confirm with the ENTER  button.

Refer to Battery Charger:VAS5908  Operating Instructions for more information on the device menu.