LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 341 (Air Conditioning (Refrigerant R134A Servicing) (Refrigerant Circuit)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Leak Detection On Refrigerant Circuit Using Leak Detection System Vas 6201 >> Adding the UV-leak detection additive to the refrigerant circuit using the A/C service station

Adding the UV-leak detection additive to the refrigerant circuit using the A/C service station

WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.

-- Add the UV-leak detection additive and the prescribed refrigerant amount using the A/C Service Station to the refrigerant circuit. Refer to Refer to REFRIGERANT R134A CAPACITIES .

NOTE:

Add 2.5 ± 0.5 cm3 of UV-leak detection additive for a refrigerant circuit with a refrigerant capacity of 100 to 150 cm 3 with the Leak Detection Kit -VAS 6201- for the Leak Detection Kit:VAS 6201  . If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV-leak detection additive must be added accordingly (for example, 5.0 ± 0.5 cm3 for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . When adding the UV-leak detection additive using the A/C service station, consult the corresponding Owner's Manual as the required amount may vary. The relevant refrigerant oil quantities in the refrigerant circuit. Refer to Refer to APPROVED REFRIGERANT OILS AND REFRIGERANT OIL CAPACITIES .

Special tools and workshop equipment required 

-- Apply a label near the service connection stating that UV-leak detection additive was added to the refrigerant circuit.

-- Start the A/C system.

NOTE:

A/C system must be operated for a minimum of 60 minutes so that the additive distributes itself in the entire refrigerant circuit (compressor must be running). Depending on the size of the leak, it may become visible under UV light within that time.

Depending on the size and location of the leak, it can now last up to several days until enough refrigerant oil with UV leak detection additive flows out to clearly determine the leaking area.

-- Find the leak in the refrigerant circuit with the UV lamp VAS 6196/4. Refer to Detecting leaks on the refrigerant circuit using UV lamp VAS 6196/4 .